ASME PCC-1 has guidelines for pressure boundary bolted flange joint which covers the assembly elements that are essential in ensuring a high level of leak-tightness integrity of properly designed and constructed bolted flange joint assemblies (BFJAs). Specifically, this standard defines BFJAs as those applied to pressure-boundary flange joints with ring-type gaskets that are entirely within the circle enclosed by the bolt holes and have no contact outside this circle.
ASME PCC-1 is not mandatory as per ASME Sec. VIII Div.1 code and being considered as an additional project specific requirement insisted by the client.
The maximum temperature limits for the materials are as follows:
These limits can vary based on specific alloys and conditions.